Nut & Cable Crimping

CC22UC

CC22

CC24

CC24

NC20

NC20

NC30

NC30

NC40

NC40

Model CC22 CC24 NC20 NC30 NC40
Crimping range (mm) 1 10 — 54 10 — 61 12 — 49 12 — 63 12 — 105
Crimping range (inches) 1 0.39 — 2.12 0.39 — 2.40 0.47 — 1.93 0.47 — 2.48 0.47 — 4.13
Crimping force (kN) 680 1300 500 660 930
Crimping force (tonnage) 68 130 50 66 93
Crimpings / hour 2 1700 1280 2100 2400 1900
Max. hose size (inches) 2 2
Die set 3 CC22 P20 NC20 NC30 NC 13
Maximum opening (mm) 4 +25 +25 +18 +26 +26
Master die (D / L mm) 84 / 52 84 / 80 99 / 22 99 / 35 140 / 37
Master die (D / L inches) 3.31 / 2.05 3.31 / 3.15 3.90 / 0.87 3.90 / 1.38 3.90 / 1.46
Control UC UC UC UC UC
Motor (kW) 3 4 3 4 4
Motor (HP) 4.0 5.5 4.0 5.5 5.5
QC tool 14 O O
Foot pedal 15 O O X X X
Control unit: integrated X X X X X
Control unit: C1
Control unit: C2
Back stop device: mechanic O O X X X
Back stop device: electric 15 X X
Mirror
UC1 O O O O O
UC2 O O O O O
UC3 O O O
Auto greasing G3 16 O O O O O
Remotic control unit O O O
Counter 18 X X X X X
ASCII signal O O O O O
Length (mm) 597 597 835 835 835
Width (mm) 475 586 885 885 885
Height (mm) 722 780 997 997 997
Length (inches) 23.6 23.6 32.9 32.9 32.9
Width (inches) 18.8 23.1 34.8 34.8 34.8
Height (inches) 28.4 30.7 39.3 39.3 39.3
Weight (kg) 125 178 220 240 240
Weight (lbs) 276 393 485 529 529

X = standard
O = optional
— = not available

  1. With standard dies. Crimping range can be increased with special dies.
  2. Theoretical with ½ hose, diameter 10 mm.
  3. See table for die set data.
  4. Maximum opening is the total die travel. Add this value to the minimum crimping diameter of the die set used. The result is the maximum opening of the machine with die set in place.
  5. 12V / 24V. Overload controlled.
  6. 1-phase / 3-phase.
  7. FP140 dies can be used without adapter dies.
  8. Hydraulic hose / industrial hose.
  9. With adapter dies.
  10. Hose cutter.
  11. Full cycle.
  12. Die travel / feeding channel.
  13. NC20, NC30 and NC40 dies can be used.
  14. Available for P20, P32 and CC22 dies.
  15. Not available in MS control.
  16. Technical implementation varies depending on the machine model. Please verify the suitability of the option from your distributor.
  17. Available in UC models only.
  18. Standard feature in UC models, includes ascending/descending counter.
18546 Nc20 702044 Nc30 703955 Nc40 18315 Cc22 18013 P20xx